Loading...
HomeMy WebLinkAbout05621ORDINANCE NO. 5621 AN ORDINANCE APPROVING A LICENSE AGREEMENT BETWEEN PUEBLO, A MUNICIPAL CORPORATION, AND THE UNITED STATES OF AMERICA FOR THE AUTOMATED SURFACE OBSERVING SYSTEM AT PUEBLO MEMORIAL AIRPORT, AND AUTHORIZING THE PRESIDENT OF THE COUNCIL TO EXECUTE SAME, BE IT ORDAINED BY THE CITY COUNCIL OF PUEBLO, COLORADO, THAT: CgVrTTnAT l . A certain License Agreement, ASOS W /OP 3/89, revised 05/31/90, a copy of which is attached hereto and made a part hereof by reference, after having been approved as to form by the City Attorney, by and between Pueblo, a Municipal Corporation, and the United States of America, relating to the use of land for the Automated Surface Observing System at Pueblo Memorial Airport to the United States Department of Commerce, National Oceanic and Atmospheric Administration, without cost, be and the same is hereby approved. SECTION 2: The President of the Council is hereby authorized to execute said License Aareement on behalf of Pueblo, a Municipal Corporation, and the City Clerk shall affix the Seal of the City thereto and attest the same. CWrTTnTT '4. This Ordinance shall become effective immediately upon final approval. INTRODUCED July 9, 1990 BY SAM UEL CORSENTINO Council Person ident of the Council U.S. Department of Commerce National Oceanic and Atmospheric Administration IRREVOCABLE LICENSE FOR USE OF REAL PROPERTY Date: 05/31/90 Grantor: City of Pueblo Address: 31475 Bryan Circle, Pueblo, CO 81001 WITNESSETH: That, in consideration of the benefits to the GRANTOR and to the UNITED STATES OF AMERICA, hereinafter referred to as the GOVERNMENT, and of the covenants and agreements to be kept and performed by the GOVERNMENT, the GRANTOR does by these presents hereby grant, at no cost, an irrevocable license for the use of the premises, services, and facilities hereinafter described or other mutually acceptable locations for the installation, operation, maintenance, repair, replacement, and removal of Automated Surface Observing System (ASOS) equipment including, but not limited to: field sensor group(s), acquisition control unit (ACU), communications and peripheral equipment, antenna(s), and connecting signal and power cables. It is covenanted and agreed that the GOVERNMENT, or the GOVERNMENT'S contractor, shall have ready and convenient access to the premises at alt times, and that the GOVERNMENT reserves the right to make such alterations, additions, and improvements as may be necessary for proper ASOS operation. It is further covenanted and agreed that all structures, fixtures, or equipment placed by the GOVERNMENT on said premises under this license, or any previous license or permit, shall be and remain the exclusive property of the GOVERNMENT, notwithstanding the same may be attached to the realty so as to become a part thereof; and that the GOVERNMENT shall have the right to remove all structures, fixtures, and equipment so erected or placed on said premises. If at any time before the expiration of this license the GRANTOR desires to change the location of the sites furnished to the GOVERNMENT pursuant to this license, or the GRANTOR changes or modifies its facilities (runways or other areas), or allows others to change or modify such facilities in such a manner so as to adversely effect or render useless the GOVERNMENT'S equipment, facilities, and /or related power, control or signal lines, any cost for repair or for removal of said equipment, facilities, and /or related power, control, or signal lines to another site acceptable to the GOVERNMENT shall be at the same expense of the GRANTOR. The terms and conditions of this license and the conditions herein shall bind the GRANTOR, and the GRANTOR'S heirs, executors, administrators, successors, and assigns. To the extent authorized by the Federal Tort Claims Act, 28 U.S.C. Sec. 2671 et seq., the GOVERNMENT assumes full control and sole responsibility for its equipment, personnel and activities incident to this license. The premises, services, and facilities to be provided by the GRANTOR pursuant to this license are described in the ASOS SITE SURVEY REPORT for the following which is incorporated herein by reference: PUEBLO MEMORIAL AIRPORT, PUEBLO, CO Dated: 05/90 (airport, city, and state) This license is effective beginning 09 /10/90 for a period of 15 years unless terminated earlier by mutual agreement. IN WITNESS WHEREOF, this license is executed as of the date first above written. GRANTOR: CITY OF PUEBLO, COL ORADO By: oe_z� MICHAEL OCCHIATO Title: PRESIDENT OF THE CITY COUNCIL THE UNITED STATES OF AMERICA U.S. Dept. of fierce, NOAA By: ��Vl_ '-f T/G Contrac 'ng Officer Special Engineering Program Office Central Administrative Support Cent ASOS W /OP 3/89 i This report summarizes the results of the site survey for the planned ASOS facility at: PUEBLO MEMORIAL AIRPORT, PUEBLO, CO DATE:05 /31/90 After analyzing the airport operations and determining the types of ASOS sensors needed, as well as other considerations such as site preparation cost, the following location was selected: Combined Sensor Group at Runway 08L: 900' N of RWY 08L -26R centerline and 3300' E of the end of RWY 08L The significant recommendations and conclusions of this report are: ■ The ACU will be located in the Terminal Building, on the second floor, in the NWS Office. ■ The wind sensor tower height is 33 feet above finished grade to the sensors. ■ The communications link from the sensor group to the ACU is by UHF radio frequency 410.075 MHz. There was no radio interference detected on this frequency. t ■ Emergency power is available for the ACU. ■ Emergency power is not available for the combined sensor group. ■ Power for the sensor group will be from an existing panel in the Electrical Vault. Power for the ACU will be from an existing panel in the Electrical Maintenance Room. ■ Power for the sensor group is to be paid by the City of Pueblo. Power for the ACU is to be paid by the NWS. r.,,4 } ..< � .'�. •: } }:o- }'<£%:: <> }•i }3 ;:•:•r,.. }r,. < }. ^':o: <•`�i}}':;r 3•} . `.r: r' 35..': %��.':'Sr'ti:��$r' <' <'.: ::.f: : ,:' + \� ..: r•'�� �••:� � `:;;<.{ Pueblo, CO Pueblo Memorial (PUB) Rev. 1 12/08/89 ABSTRACT This report summarizes the results of the site survey for the planned ASOS facility at Pueblo Memorial Airport in Pueblo, Colorado. After analyzing the airport operations and determining the type of ASOS sensor groups required, as well as other considerations such as site preparation costs, a planned ASOS facility site was selected near the existing glide slope installation at Runway 08L. The significant recommendations and conclusions of this report are: Site Location: ASOS Group Type: ACU Location: Wind Sensor Tower Height: Communications Link to ACU: Other Significant Items: Combined Sensor Group: 510 feet north of Runway 08L -26R centerline and 1209 feet east of end of Runway 08L. Combined Sensor Group Second floor, Terminal Building - National Weather Service Office Non - standard; 28 feet above finished grade to sensors. By UHF radio link to sensor group. Recommended radio frequency is 410.075 MHz. No radio interference was detected at the airport on the above frequency. Power is available at the existing glide slope installation from an existing transformer. Emergency power is available at the glide slope shelter. The existing NWS centerfield wind tower is an obstruction and it does not meet FAR Part 77 criteria. The wind tower, sensors, and supports need to be removed flush with the existing grade after ASOS commissioning. i